Stair Calculator: Risers, Treads, Stringers and Landings

Risers, treads, stringers and landings with a live drawing and code checks.

Built by Toolsque Team · last updated October 25, 2026 · checked against our testing process

Your stair-
Total run-
Stair angle-
Stringer length-
Stairwell opening-

    1Total rise

    Measure from the finished floor at the bottom to the finished floor at the top.

    2Stair type

    3Steps

    Tread depth is measured nosing to nosing (the run of each step), not the board width.

    More settings

    Upper floor depth (joists plus floor and ceiling) sets how long the stairwell opening must be for full headroom.

    1. Measure the total rise: finished floor to finished floor, and pick US (inches, IRC) or UK (millimetres, Part K).
    2. Choose the stair type: straight, with a landing, deck or outdoor, or concrete steps.
    3. Adjust the riser and tread: the drawing and the code check update as you type; red means a rule is broken.
    4. Read the stringer cut list: the framing square settings, the first step drop and the board length to buy.
    5. Print the sheet: take the drawing and the numbers to the job, or save them as a PDF.

    How to measure total rise

    Every stair starts from one number: the total rise, measured from the finished floor at the bottom to the finished floor at the top. If the flooring is not down yet, add its thickness now. A stair laid out on bare subfloor ends up with a short top or bottom step once 3/4 in of hardwood or 20 mm of tile goes down, and that one odd step is what trips people.

    Measure at the point where the stair will actually land, not at a corner of the room. Floors are rarely level over a long run, so on a deck or a garage with a sloping slab, hold a straightedge level from the top floor out over the landing spot and measure down from it.

    How many stairs do I need?

    Divide the total rise by a comfortable riser height and round to the nearest whole number. That is your number of risers. Then divide the total rise by that number to get the exact riser height, which will almost never be a round number, and that is fine.

    • 105 in total rise at a 7.5 in target: 105 / 7.5 = 14 risers of exactly 7.5 in.
    • 107 in total rise: 107 / 7.5 = 14.3, so 14 risers of 7.643 in (about 7-5/8 in).
    • 2,600 mm in the UK at a 190 mm target: 2,600 / 190 = 13.7, so 14 risers of 185.7 mm.

    The number of treads is one fewer than the number of risers, because the upper floor itself is the last step. The calculator never lets rounding push a riser over the code maximum: if it would, it adds a riser.

    Rise and run rules: US IRC and UK Part K

    Use the switch at the top of the tool to check against the rules where you build. Each line turns green or red, and failing items turn red on the drawing too.

    Scroll table →
    RuleUS, IRC R311.7 (homes)UK, Approved Document K (private stair)
    Riser height7-3/4 in maximum150 to 220 mm
    Tread depth (going)10 in minimum, nosing to nosing220 to 300 mm
    Steepnessset by riser and tread42 degrees maximum
    2 risers + 1 goingnot in the code550 to 700 mm
    Nosing3/4 to 1-1/4 in where the tread is under 11 intreads must overlap on open risers
    Headroom6 ft 8 in2.0 m (loft conversion: 1.9 m at the centre, 1.8 m at the side)
    Width36 in minimumno minimum for a private stair
    Height of one flight151 in maximum, then a landinglanding at the top and bottom of every flight
    Riser variation3/8 in maximum across a flightall rises in a flight equal

    Local amendments exist on both sides of the Atlantic, so your building department or Building Control has the final word. Commercial and public stairs follow stricter rules (IBC 1011 in the US, the general access tables of Part K in the UK) that this calculator does not check.

    What makes a stair comfortable

    A stair can pass code and still feel wrong. The test most carpenters use is two risers plus one tread: between about 24 and 25-1/2 in in the US, or 600 to 640 mm in the UK (the middle of Part K's 550 to 700 mm band). A 7.5 in riser with a 10.5 in tread gives 25.5 in, the classic house stair. Shorter risers need deeper treads to keep the same stride: 7 in risers pair with 11 in treads.

    Steeper than about 40 degrees starts to feel like a ladder going down, which is why Part K caps private stairs at 42 degrees. Shallower than about 30 degrees eats floor space fast without feeling much easier.

    How long does a stair stringer need to be?

    The stringer is the diagonal of the rise and the run: the square root of rise squared plus run squared. For a 105 in rise over a 136.5 in run that is about 172 in, or 14 ft 4 in. Buy stringer stock at least a foot longer to allow for the plumb cut at the top and the level cut at the bottom. In the US that usually means a 16 ft 2x12.

    Leave enough solid wood below the notches. A cut stringer is only as strong as the wood left under the deepest notch, and AWC's DCA 6 deck guide calls for at least 5 in of it on deck stairs.

    Cutting the stringer: the cut list

    1. Set the framing square. Put stair gauges at the riser height on the tongue and the tread depth on the blade.
    2. Mark from the top. Trace one rise and one tread, slide the square along, and repeat for every tread in the cut list.
    3. Drop the first step. Cut the tread thickness off the bottom of the stringer. Without that, the first step comes out taller than the rest by the thickness of the tread.
    4. Use one template. Cut the first stringer, check it in place, then trace every other stringer from it so all of them match.

    Stairs with a landing

    Choose "With a landing" and the calculator splits the rise into two flights with a flat landing between them, and shows two stringer lengths. In the US a landing is required once a single flight would rise more than 151 in, and it must be at least 36 in deep in the direction of travel. In the UK every flight needs a landing at the top and bottom, at least as long as the stair is wide. Landings also let a stair turn 90 degrees (an L stair) when the straight run will not fit.

    Deck stairs

    Outdoor stairs usually use two deck boards per tread, which is why the deck setting starts with an 11-1/4 in tread. Stringers should sit no more than 16 in apart for 2x or 5/4 decking, so a 36 in stair needs four. Set the bottom of the stringers on a concrete pad or compacted gravel, never on bare soil, and fasten the top with hangers or a ledger rated for stairs. The joist span calculator counts the nails and screws for the deck frame by weight.

    Concrete steps

    For solid concrete steps, the calculator adds up the concrete in each step: the lowest step is one riser tall, the next two, and so on, across the full width, plus any top platform. It gives the volume and the number of 80 lb or 60 lb bags (25 kg or 20 kg in the UK) with 10 percent extra. Three 7 in risers with two 11 in treads, 48 in wide, come to about 6.4 cu ft. Anything much bigger is usually cheaper as ready-mix; the concrete bag calculator compares the two.

    Stairwell opening and headroom

    The opening in the upper floor has to be long enough that nobody walking up hits their head on its edge. The calculator works it out from the headroom (6 ft 8 in, or 2.0 m) plus the depth of the floor structure, divided by the riser height, times the tread depth. With 7.5 in risers, 10.5 in treads and a 10 in deep floor, the opening needs to be about 126 in long. The dashed blue line on the drawing is the headroom line: anything above the stair and below that line is too low.

    In a UK loft conversion the headroom can drop to 1.9 m at the centre of the stair and 1.8 m at the side, which is often what makes a loft stair fit at all. The loft head height calculator checks the room it lands in.

    Worked example: stairs computation in metric

    Floor to floor height 2,800 mm, with a target riser of 175 mm:

    1. Risers: 2,800 / 175 = 16 risers, each exactly 175 mm.
    2. Treads: 16 - 1 = 15 treads. At 270 mm each, the total run is 15 x 270 = 4,050 mm.
    3. Check: 2R + G = 2 x 175 + 270 = 620 mm, inside both the Part K band (550 to 700 mm) and the comfortable range (600 to 640 mm). Pitch = atan(175 / 270) = 33 degrees, under 42.
    4. Stringer: the square root of 2,800² + 4,050² = 4,924 mm, so buy 5.2 m lengths.
    5. Opening: (2,000 + 250) / 175 = 12.9, so 13 goings x 270 mm = 3,510 mm of opening for full 2.0 m headroom under a 250 mm floor.

    Related tools

    Adding a stair to a new floor? Size the joists with the joist span calculator, price a platform with the mezzanine floor calculator or a whole loft with the loft conversion cost calculator, and work out a roof's angle with the roof pitch calculator. To price the job, use the job costing calculator.

    Frequently Asked Questions

    How do I calculate how many stairs I need?

    Divide the total rise (finished floor to finished floor) by a comfortable riser height, about 7.5 in or 180 to 190 mm, and round to the nearest whole number. That is the number of risers. Divide the total rise by it again for the exact riser height. The number of treads is one fewer than the risers.

    What is the ideal stair rise and run?

    About 7 to 7.5 in of rise with a 10.5 to 11 in tread in the US, or about 175 to 190 mm rise with a 250 to 280 mm going in the UK. Check it with two risers plus one tread: 24 to 25-1/2 in, or 600 to 640 mm, feels natural.

    What is the maximum stair riser height allowed?

    In US homes the IRC allows 7-3/4 in at most, with a tread of at least 10 in. For a UK private stair, Approved Document K allows a rise of 150 to 220 mm with a going of 220 to 300 mm and a pitch of no more than 42 degrees. Local rules can be stricter.

    How long should a stair stringer be?

    The square root of rise squared plus run squared, plus about a foot (300 mm) for the end cuts. A 105 in rise over a 136.5 in run needs about 172 in, so buy a 16 ft board.

    How many stringers do I need for stairs?

    Space them no more than 16 in (400 mm) apart. A 36 in or 48 in wide stair needs four stringers, and a 60 in stair needs five. Use closer spacing for thin treads or composite decking.

    When does a stair need a landing?

    In the US, when one flight would rise more than 151 in (12 ft 7 in); the landing must be at least 36 in deep. In the UK, every flight needs a landing at the top and bottom, at least as long as the stair is wide.

    How much headroom does a stair need?

    6 ft 8 in over the whole length of a US home stair, and 2.0 m in the UK, reduced to 1.9 m at the centre and 1.8 m at the side for a loft conversion stair.

    How do I work out the stairwell opening?

    Add the headroom to the depth of the upper floor, divide by the riser height, round up, and multiply by the tread depth. With a 7.5 in riser, 10.5 in tread and 10 in floor, the opening needs to be about 126 in long.

    How much concrete do I need for steps?

    Add up each step: the lowest is one riser tall, the next two, and so on, times the tread depth and the width. Three 7 in risers with two 11 in treads, 48 in wide, need about 6.4 cu ft, or 12 bags of 80 lb concrete with 10 percent extra.

    Why is my first step a different height?

    Because the bottom of the stringer was not cut down by the tread thickness, or the finished flooring was not counted in the total rise. Every riser must match: the IRC allows only 3/8 in of difference across a flight.